How Many Radials Does a 40m Vertical Need?

Mike Markowski, mike.ab3ap@gmail.com

Problem Considered: A quarter-wave vertical is only half of an antenna—the earth beneath it forms the other half, and plain soil turns transmitter power into heat. Laying down radial wires gives return currents a low-loss path back to the feedpoint. Using pynec81 (NEC-2) and pynec5 (NEC-5), this study sweeps 1 to 256 radials on 40m (7.15 MHz) to show when adding more wire stops making an on-air difference.
40m Vertical Radial Sweep from 1 to 256 radials
40m quarter-wave vertical (10.1 m radiator, 10.0 m radials) over average soil (εr = 13, σ = 0.005 S/m), comparing radials slightly above ground (z = 0.02 m) with buried radials (z = -0.05 m).

1. Five Takeaways for Vertical Builders

1. The “Half-Power” Surprise: Elevated vs. Buried

Look at the top graph (Gain at 20° El). Even 256 buried radials (green line, -4.2 dBi) still trails 16 slightly elevated radials (blue line, -1.4 dBi) by nearly 3 dB. In radio terms, 3 dB is half your transmitter power: burying 256 wires in the dirt still loses half your power heating the soil compared to lifting just 16 wires a single inch (2 cm) above the grass.

2. What the “0.3 dB Knee” Means—and When to Stop

In engineering, the “knee” of a curve is the bend where a steep climb flattens into a plateau. The middle bar chart measures how much extra signal you earn each time you double your radial count (1→2, 2→4, and so on):

3. The “1:1 SWR Trap” in the Bottom Graph

When you measure feedpoint resistance at the base of a vertical with an antenna analyzer, you are measuring two resistances added together:

Rmeasured = Rradiation + Rground loss

An ideal quarter-wave vertical over a lossless ground has a radiation resistance (Rradiation) of about 36 Ω. Any resistance above 36 Ω is wasted soil resistance warming the yard:

4. Why NEC-81 and NEC-5 Differ at 1–8 Radials

Both solvers converge on the same answer once you reach 32+ elevated radials (-1.0 to -1.2 dBi gain and ~36–41 Ω resistance). With only 1 to 8 elevated radials, classic NEC-81 (NEC-2) predicts much higher ground loss (239 Ω, -8.7 dBi) than NEC-5 (84 Ω, -4.4 dBi). NEC-2’s older thin-wire ground approximation overestimates near-field loss when wires sit just 2 cm (0.00048λ) above the interface, whereas NEC-5’s Mixed-Potential Integral Equation (MPIE) models fields arbitrarily close to—and beneath—the surface accurately.

5. Modeling Note: The “Blip” at 128 Elevated Radials

Why does the orange NEC-5 curve jump at 128 radials? For 1 through 64 radials, all radial wires meet directly at the center point (0, 0, z). At 128 and 256 radials, crowding that many wires into a single point places adjacent segments only millimeters apart. To avoid wire-overlap artifacts, the 128- and 256-radial elevated models connect the radial fan to a 0.50 m diameter hub ring fed by 8 spokes—causing the slight step at 128 before settling back onto -1.0 dBi at 256.

2. Complete Simulation Data (7.15 MHz)

Gain values below are azimuth-averaged far-field total gain at 20° elevation (θ = 70°), representative of 40m DX propagation:

Radials NEC-81 Elev. (0.02 m) NEC-5 Elev. (0.02 m) NEC-5 Buried (-0.05 m)
Gain (dBi) Rin (Ω) Gain (dBi) Rin (Ω) Gain (dBi) Rin (Ω)
1 -8.69239.2 -4.3683.8 -8.95260.4
2 -5.65120.0 -3.8976.5 -8.83256.1
4 -3.3169.1 -3.5469.3 -8.57244.0
8 -1.9449.9 -3.3364.2 -8.06215.5
16 -1.3543.0 -2.2849.8 -7.25176.2
32 -1.2141.1 -0.8636.3 -6.32139.8
64 -1.2340.7 -0.6034.8 -5.49113.8
128 -1.2440.7 +0.9226.0 -4.8197.5
256 -1.2440.7 -0.9834.9 -4.2485.4

3. Practical Checklist for Your Yard